DC Current is
the full load or
peak bias
current. Enter
zero if there is
no bias
current.
Peak Current
Inductance is
the inductance
required with
full load bias
current plus
ripple current.
Specified
Current is any
RMS or bias
current of
interest.
Click the Find Part
Numbers
button to show suggested
Magnetics® cores in the
Magnetics Part
Numbers box
that fit the input
parameters.
In Step 2,
enter one of the
suggested Magnetics Part
Numbers (or any valid
Magnetics part number).
Click the Design
Output button
to see the results in
the Design Output box.
In the Adjust
section, you may adjust
turns, wire size, or
wire strands if
desired by entering new
number. When finished,
click the Design
Output button
in Step 2.
The default wire
selection is
only for 1
strand. Software
is based on
current
density of 500
Amps/cm².
When the current
is larger than
66.5 Amps, the
default wire
will be 6 AWG
for 1 strand.
Please consider
using multiple
wires when
current or
frequency is
high.